MDE883 - Elliot Gold™ Series Central Workstation with rotation, tilt and transverse motion
- Stock: In stock - Contact us for lead times.
- Click here to: Contact us
- Model: Martock MDE883
Elliot Gold™ Central Workstation with Rotation, Tilt and Transverse Motion
MDE883
Optical workstation with 2 axes of precision rotation, 1 axis of tilt and 2 axes of linear travel.
- ± 4° adjustment, 1 arc sec resolution for θx and θz
- ± 1° for θy
- 25 mm travel, 0.5 µm resolution for Y axis
- Direct readout of device Y linear travel position.
- 6 mm travel, > 2 µm resolution for Z axis
- Mounts directly onto 25 mm or 1" pitch table
The Central Workstation provides roll (θx) and pitch (θy) at a height of 125 mm from the bottom of the base plate and these both coincide with the yaw (θz) axis at a height of 18 mm above the middle of the top plate of the θz rotation unit. Rotation axes are defined by curved bearings hence rotation is always in a true arc. Digital readout of the Y travel is provided to allow the operator to read waveguide positions. Thus stepping the fibre across the substrate to locate individual waveguides becomes a simple task.
Application Note
The MDE883 Central Workstation was designed to be a key part of the MDE881 6-axes manipulator. However for applications where the geometry of the standard MDE881 is not suitable we offer the system in its key component parts, allowing custom set-ups to be configured on an optical table or breadboard. This approach means that the system can be purchased in parts as required.
Thus the MDE883 can be used in situations where the standard in-line configuration of the MDE881 is not suitable. For example when the waveguide inputs and outputs are angled at 90 degrees. Alternatively, building the system in kit form provides greater flexibility in adapting the modules to a wider range of applications.
Specifications
θx | ± 4° rotation with 1 arc sec resolution |
θz | ± 4° rotation with 1 arc sec resolution |
θy | ± 1° rotation adjustable by hex key supplied with MDE881. Adjustment is useful for aligning to waveguides mounted on epoxy in packages where device is not necessarily sitting flat. |
Y-travel | 25 mm standard (MDE883) with 0.5 µm resolution and direct digital read-out of position to 1µm (with digital micrometer) |
Z-travel | 6 mm with 2 µm resolution by means of hex key adjuster |
Axis height | 125 mm from bottom of base plate |
Includes | Model MDE154 clamp set |
Options and Accessories | |
MDE883-60 with 60 mm of Y-travel | |
MDE890 and MDE891 can be used to extend the rotation range - useful for holding components such as Fabry-Perot filters |
File Name | Size | Link |
---|---|---|
Terms and Conditions V6 | 207.42KiB | Download |